Flash Pen Infrared-Thermometer


Artical: TFA31.1125
Brand: TFA
Origin: Germany
Availability: In stock
Made by: Plastic
Size :
19 x 87 x 15 mm
No. Of Pieces: 1
Barcode:

Price : 15.000 KD
Quantity:

FLASH PEN – Infrared Thermomete

1. Before you use it
• Please be sure to read the instruction manual carefully. This information will help you to familiarise yourself with your new device, learn all of its functions and parts, find out important details about its first use and how to operate it, and get advice in the event of faults.
• Following the instruction manual for use will prevent damage to the device and loss of your statutory rights arising from defects due to incorrect use. We shall not be liable for any damage occurring as a result of not following these instructions. Likewise, we take no responsibility for any incorrect readings and for any consequences which may result from them.
• Please take particular note of the safety advice!
• Please look after this manual for future reference.

2. Scope of supply
• Infrared Thermometer
• Batteries 4 x LR44
• Instruction manual
• Storage case

3. Field of operation and all of the benefits of your new instrument at a glance
• For contact-free measuring of surface temperature in less than 1 second.
• Simply aim at the object to be measuring and press the button.
• Metal housing with clip
• For many uses in household, hobby and business.

4. For your safety
• The product is exclusively intended for the field of application described above. The product should only be used as described within these instructions.
• Unauthorised repairs, modifications or changes to the product are prohibited.
• The product is not be used for medical purpose or for measuring body temperatures or for public information, but is intended only for home use.

Caution! Risk of injury:
• Do not aim too close at hot or dangerous targets!
• Keep this instrument and the batteries out of reach of children.
• Batteries must not be thrown into the fire, short-circuited, taken apart or recharged. Risk of explosion!
• Batteries can be fatal if swallowed. If a battery has been swallowed, get medical assistance immediately.
• Batteries contain harmful acids. Low batteries should be changed as soon as possible to prevent damage caused by a leaking battery.
• Wear chemical-resistant protective gloves and glasses when handling leaked batteries.

 Important information on product safety!
• Do not place the instrument near extreme temperatures, vibration or shock.
• Protect the unit from large or abrupt temperature changes.
• Do not leave the unit near objects of high temperature.
• Do not immerse the unit into water. Water can penetrate and cause malfunction.
Protect from moisture.
• Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit’s optics.
• Protect the instrument from EMI (Electro Magnetic Interference) from induction heaters and microwave ovens and Electro Static Discharge.

5. Elements
A: Sensor
B: LCD
C: Clip
D: Operating button
E: C/°F button
F: Batteries
G: Battery compartment lid

6. Operation
• Just aim at the measuring object and press the operating button. Read the surface temperature in less than a second. When the button is released, the last temperature reading will hold on the display for 15 seconds. The instrument will automatically switch off.
Distance, Spot Size, and Field of View
• As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger a ratio D:S = 1:1 (e.g. 10 cm distance = 10 cm spot size). To get the most accurate temperature reading, aim at the target as near as possible.
Please take note of the following
• Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.).
• The unit cannot measure through transparent surfaces such as glass or plastic. It will measure the surface temperature of the glass instead.

7. Display change °C/°F
• Use a pin for to press the °C/°F button at the rear side and the temperature unit can be changed from °C (grade Celsius) to °F (grade Fahrenheit).

8. Care and maintenance
• The sensor lens is the most delicate part of the thermometer. Please protect the sensor part from dirt.
• Clean the instrument with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the batteries if you do not use the product for a lengthy period.
• Keep the instrument in a dry place.

8.1 Battery replacement
State 1 State 2 State 3
• The battery symbol appears permanently on the display.
• Change the batteries when state 3 appears on the display.
• Important: Confirm the unit is power off before changing battery.
• Open the battery compartment by turning the lid counterclockwise and insert the two new replacement batteries (LR44). Make sure they have the correct polarity (+ pole above).

9. Troubleshooting
Problems Solutions
No display ➜ Press the operating button
➜ Ensure batteries polarity are correct (+ pole above)
➜ Change batteries
Display “oFF” ➜ Automatic switch-off
Display “Hi” ➜ Temperature > 220°C
Display “Lo” ➜ Temperature < -33°C
Incorrect display ➜ Change batteries
If your device fails to work despite these measures contact the supplier from whom you purchased it.

10. Waste disposal
This product has been manufactured using high-grade materials and components which can be recycled and reused.
Never dispose empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to appropriate collection sites  depending to national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead.
This instrument is labelled in accordance with the EU Waste
Electrical and Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste.
The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal.

11. Specifications
Measuring range
Temperature: -33°C...+220°C (-27,4°F…+428 °F)
Operating environment: 0°C...+50°C (+32°F…+122°F)
Storage range: -20°C …+65°C (-4°F …+149°F)
Accuracy: ±2°C or 2% of reading (whichever is greater)
Resolution: 0,1°C/0,1°F
Response time: approx. 1 second
Emissivity: 0.95 only
Optical resolution: 1:1
Automatic switch off: 15 seconds
Power consumption: Button cell batteries 2 x LR44
Dimensions: 87 x 18 x 16 mm
Weight: 98.3 g (incl. batteries and storage case)

The technical data are correct at the time of going to print and may change without prior notice.